Function
Analog inputs
Resolution: 16 bits
Measuring ranges:
±2.5 V, ±5 V, ±10 V, ±20 V
2.3 Measuring Range Adjustment of the Analog
Inputs
The measuring range of each analog input with 16-bit resolution (AIn16) can be set in
4 steps by configuration:
±2.5 V
±5 V
±10 V
±20 V
The measuring range of the analog inputs with 12-bit resolution (AIn12) is fixed at
10 V (except AIn12_7: 30 V) and cannot be changed.
2 Connectors
PCAN-MicroMod FD Analog 1
User Manual 1.2.0
© 2021 PEAK-System Technik GmbH
A
Pin
AIn16_7
8
AIn16_6
7
AIn16_5
6
AIn16_4
5
AIn16_3
4
AIn16_2
3
AIn16_1
2
AIn16_0
1
B
AIn12_3
AIn12_2
AIn12_1
Measuring range: 0 – 10 V
AIn12_0
AOut_3
AOut_2
AOut_1
Voltage range: 0 – 10 V
AOut_0
Function
Analog inputs
Resolution: 12 bits
Analog outputs
Resolution: 12 bits
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipeh-003087

Table of Contents