I/O (Right Connector) - Peak PCAN-MicroMod FD User Manual

Hide thumbs Also See for PCAN-MicroMod FD:
Table of Contents

Advertisement

Pin Identifier Function
3
CAN_L
High-speed CAN connection (ISO 11898-2)
4
CAN_H
5
Fout_0
Frequency outputs (up to 10 kHz)
6
Fout_1
Start the CAN bootloader for a firmware
update via CAN
7
Boot
(High-active, connection to Ub during the
start-up of the motherboard)
8
AIn12_7
Analog input 7 (0 - 30 V, resolution 12 bits)
9
UART_Rx
Serial RS-232 interface
10
UART_Tx
For the startup of the PCAN-MicroMod FD Analog 1 it is sufficient to connect a voltage
source to pins 1 and 2. The configuration of the PCAN-MicroMod FD Analog 1 is done
via the CAN bus being connected to pins 3 and 4. Read more in 5 Configuration Soft-
ware on page 15.

2.2 I/O (right connector)

Function
Ground
Digital inputs
2 Connectors
PCAN-MicroMod FD Analog 1
User Manual 1.2.0
© 2021 PEAK-System Technik GmbH
Right connector 2 x 11 terminals
A
Pin
GND
11
DIn_1
10
DIn_0
9
Comment
Internal termination resistor 120 Ω can
be activated.
See 4.2 Activate Internal CAN Bus Termin-
ation on page 13.
Activity LED quickly blinks orange when
CAN bootloader is active
General tasks, e.g. voltage monitoring
or threshold switch
Corrently no use
B
5-Volt supply for external devices
5Vout
DIn_3
DIn_2
Function
(max. 100 mA)
Digital inputs
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ipeh-003087

Table of Contents