4 Optional Hardware Settings

Two settings for special cases can be defined on the circuit board of the PCAN-
MicroMod FD Analog 1:
Several MicroMod-FD-based devices are to be configured on the same bus:
4.1 Set Device ID below
The PCAN-MicroMod FD Analog 1 is to be used on one end of a CAN bus that is not
fully terminated (for example, when two CAN nodes are connected directly):
4.2 Activate Internal CAN Bus Termination on page 13

4.1 Set Device ID

If you use several devices with PCAN-MicroMod FD on a single CAN bus and want to
configure them there, a unique device ID must be assigned to each PCAN-MicroMod
FD, so the configuration program can distinguish the modules. This is done by a
rotary switch with 16 positions (0 to F, hexadecimal) on the board.
The device ID of a PCAN-MicroMod FD does not have an effect on the CAN commu-
nication.
Note: On a can bus, up to 16 PCAN-MicroMod FD can be
configured. The operation of more than 16 modules is possible,
as long as you do not want to configure them on that bus.
4 Optional Hardware Settings
User Manual 1.2.0
© 2021 PEAK-System Technik GmbH
PCAN-MicroMod FD Analog 1
11