5
Align the axis slideway with the readhead bracket and secure using M4
screws.
7
Align the readhead with the readhead mounting bracket and secure with M4
screws and nuts.
36
FORTiS-N Functional Safety enclosed encoder system – original instructions
6
Remove the screws and nuts from the mounting aid, unlock and remove
from the extrusion.
8
Using the correct tool, tighten the screws to a torque of 2.5 Nm.
NOTE: Secure fastenings with Loctite 243.
2.5 Nm