14.4 Installation with mounting spar

Renishaw recommends the use of a mounting
spar where measuring lengths are greater than
620 mm. This requires encoders with short
end caps. Where measuring lengths are less
than 620 mm, if short end caps are specified,
the mounting spar should also be used. If in
doubt, please contact your local Renishaw
representative.
The spar should be installed prior to fitting the
encoder.
NOTE: Secure fastenings with Loctite 243.
1
Place the mounting spar on the mounting surface and firmly push
against the mounting edge/dowel pins. Position the spar to align to
the surface mounting holes. Loosely secure the mounting spar to the
mounting surface with appropriate M6 screws.
NOTE: Secure fastenings with Loctite 243.
3
Position the encoder against the spar.
Inset: Ensure the clips on the mounting spar engage correctly with
the extrusion profile.
2
//
0.1 mm
X
Use a dial gauge to ensure the mounting spar is set to the correct
parallelism compared to the machine guideway. Once aligned tighten
the screws to a torque of 8 Nm.
X = Machine guideway axis/datum.
4
Tighten the screws on the top of the mounting spar to secure the
encoder firmly to the mounting spar.
Tighten all bolts, working from left to right.
8 Nm
2 Nm
www.renishaw.com