Extrusion Installation Without Mounting Spar - Renishaw FORTiS-N Installation Manual

Enclosed encoder system
Table of Contents

Advertisement

14.3 Extrusion installation without mounting spar

1
Place the encoder on the mounting surface and firmly push against
the mounting edge/dowel pins. Position the encoder to align the
mounting holes.
3
Tighten to a torque of 20 Nm.
26
FORTiS-N Functional Safety enclosed encoder system – original instructions
2
Loosely secure the extrusion to the mounting surface with the two
supplied serrated washers and M8 screws placed in the end cap
mounting holes.
NOTE: Secure fastenings with Loctite 243.
20 Nm