12 Installation drawings

12.1 Mounting surface preparation

To ensure correct operation, the mounting surface should be prepared as follows:
surface flatness requirement of 0.05 mm/m
surface should be free of paint and burrs
refer to installation drawing for required mounting hole positions (see
To further simplify and help reduce installation time, it is recommended that the machine axis to
which the encoder is to be mounted is prepared with a datum edge or aligned dowel pins to help
locate the edge of the extrusion and ensure parallelism to the axis of motion.
> ML + 138 (* > ML +105)
> 32
> 13
> 96
20
FORTiS-N Functional Safety enclosed encoder system – original instructions
section 12.5
on page 22).
Dimensions and tolerances in mm
M8 (M4*)
0.05
M4
* M4 for short end cap version.
12.2 Datum location edge or dowel pins
– standard end caps
B
> 5.5
Machine edge
R1 max.
mounting
//
0.1
//
0.1
B
KEY
X = Machine guideway/axis datum
NOTES:
1.
Side elevations show alternative mounting orientations.
2.
Alignment pin and machine edge mounting options to mate directly to the top face of the
extrusion.
Dimensions and tolerances in mm
B
> 5.5
Alignment pin
X
//
//
0.1
B
0.1
X

Advertisement