Installation Procedure - Readhead; Start Of Measuring Length - Standard; Start Of Measuring Length - Short End Caps - Renishaw FORTiS-N Installation Manual

Enclosed encoder system
Table of Contents

Advertisement

15 Installation procedure – readhead
Three different methods may be used to install the readhead, making installation easier for a wide
range of machine types and mounting surfaces. These are outlined in the following sections.
NOTE: Installation of the extrusion follows the procedure outlined in
is independent of the readhead installation method being used.
15.1 Start of measuring length – standard
The start of the measuring length (ML) is indicated by the triangular marking on the extrusion;
a corresponding arrow on the readhead should be aligned to this arrow to ensure the readhead is
within the encoder measuring length.
19.5 ±1
ML
S
KEY
ML = Measuring length
S = Start of measuring length
WARNING: Failure to ensure the readhead is within the measuring length of the encoder could
lead to a collision and damage.
30
FORTiS-N Functional Safety enclosed encoder system – original instructions
15.2 Start of measuring length – short end caps
section 14
on page
25
and
Dimensions and tolerances in mm
KEY
ML = Measuring length
S = Start of measuring length
1 ±0.5
ML
S
Dimensions and tolerances in mm