14.5 Mounting spar installation drawing

B
//
0.1
X
0.05
28.25
1.15 ±0.05
B
7.7
12
48.1
26
D
D
10 ±0.2
View showing system
//
0.1
B
mounted in reverse
KEY
D = Required mounting dimensions
ML = Measuring length
P = Gauging points for alignment
X = Machine guideway/axis datum
28
FORTiS-N Functional Safety enclosed encoder system – original instructions
(ML 620 mm shown)
(ML/2 + 62.5) ±10
70 ±5 ML ≥ 170
30 ±5 ML  < 170
7.5
P1
13
36.1
18 ±0.2
D
10 ±0.2
D
//
0.1
B
37.5
ML
70
120
170
220
270
320
370
L
37.5
55
75
100
115
140
175
n
-
-
-
-
-
-
(ML + 105) ±0.4
(n × 200) ±0.5
D
P3
(n × 200) ±0.5
55
55
L
D
(ML/2 +15) ±0.5
Section B–B through the spar
420
470
520
570
620
670
720
200
225
250
275
300
325
350
-
-
-
-
-
1
1
1
Dimensions and tolerances in mm
ML ≤ 820 P1
P2
ML > 820 P1 . . . P3
//
0.1
X
Detail A
SW3
(3 mm hex key)
Showing clamp installed
770
820
920 1020 1140 1240 1340 1440 1540 1640 1740 1840 2040
375
400
450
500
550
640
655
710
1
1
1
2
2
2
2
3
70 ±5 ML ≥ 170
30 ±5 ML < 170
3 × M5
P2
Ø6.6
Ø12.9
B
10.3
B
Detail A
760
810
855
910 1010
3
3
3
4
4