Rtlc40 / Fastrack System Installation Drawing - Renishaw QUANTiC RTLC40 Installation Manual

Incremental linear encoder system
Hide thumbs Also See for QUANTiC RTLC40:
Table of Contents

Advertisement

RTLC40 / FASTRACK system installation drawing

1 minimum (gap)
10 maximum (gap)
10
3.7
18 ±0.1
15
Optional end cover
3
1.5
NOTES:
The minimum recommended FASTRACK carrier length is 100 mm.
The reference mark selector and limit actuator locations are correct for the readhead orientation shown.
External magnetic fields greater than 6 mT, in the vicinity of the readhead, may cause false activation of
the limit and reference sensors.
12
QUANTiC
RTLC40 /FASTRACK
Measuring length ML = (L − 10) (ML = (L − 25) with dual limits)
FASTRACK length = (L − 24)
Reference mark selector magnet
(dimensions as P limit)
9.2
P and Q limit switch sensor position
P limit magnet
Nominal P limit trigger point
Optical centreline (incremental and reference mark)
incremental linear encoder system
Overall length (L + 12)
Scale length (L)
1
RTLC40 scale
15 ±1
Two locations for spots of Loctite
to secure the axis datum position
0.5
F
0.1 / 100
Q limit magnet (dimensions as P limit)
F = axis of motion
Nominal Q limit trigger point
0.05
F = axis of motion
1
2
3
Dimensions and tolerances in mm
35 maximum
® 
435
2
18
FASTRACK carrier
F
Assumes a 1 mm gap between the scale and the end covers and a zero gap between
the FASTRACK carrier and the end covers.
For alternative mechanical datum clamp methods see
page 18.
Dimension from the FASTRACK carrier surface.
5
Ra 3.2
'Fitting the datum clamp'
on

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fastrack rtlc40

Table of Contents