Emerson Rosemount 5408 Reference Manual page 172

Level transmitters
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Specifications and reference data
March 2023
Purging connection
Option code PC1 is for cone antennas only, and requires matching flange and antenna
sizes. Note that all parabolic antennas come with an integrated air purge connection.
A minimum gasket thickness of 0.125 in. (3.2 mm) is required for flanges with protective
plate design.
Code
Description
PC1
Purging connector (purge ring)
Welding standard for flanges
Only applies to flanged process connections with welded construction or protective plate
design; only applicable to cone antennas.
Flanged process connections with protective plate design are only available with ASME IX
(option code AW).
Code
Description
AW
According to ASME IX
EW
According to EN-ISO
Country certification
CRN is not available with EN1092-1 or JIS B2220 flanges, neither for ASME B16.5 flanges in
materials of construction code M, nor 4-in. process connection with Tri Clamp.
Forged one-piece flange will be provided instead of welded construction for ASME B16.5
Class 300 raised face flange size 2-in., 3-in., or 4-in., and ASME B16.5 Class 150 raised face
flange size 8-in.
Code
Description
J1
Canadian Registration (CRN)
Hydrostatic testing
Hydrostatic testing is only available for cone antennas and process seal antennas with
flanged process connections.
Code
Description
Q5
Hydrostatic testing, including certificate
Material traceability certification
Certificate includes all pressure retaining and wetted parts.
Code
Description
Q8
Material traceability certification per EN 10204 3.1 (2.1 for non-metallic)
Hygienic certification
Only available for process seal antennas with Tri Clamp connection.
Code
Description
QA
Certificate of compliance to 3-A
172
®
Reference Manual
00809-0100-4408
Reference Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5408:sis

Table of Contents