Canon imageRUNNER ADVANCE System V3.13 Service Manual page 154

Table of Contents

Advertisement

No
Code
Character strings
.
37
8xxx 2046
Server certificate expired
38
8xxx 2047
Server response time out
39
8xxx 2048
Service not found
40
8xxx 2052
URL error
41
8xxx 2058
Unknown error
42
8xxx 2063
SOAP Fault
43
xxxx xxxx
Device internal error
44
xxxx xxxx
SUSPEND: Initialize Failure!
Cause
• The root certificate regis-
tered on the device has ex-
pired.
• The root certificate regis-
tered by the user at first is
used and the correct certifi-
cate has not been regis-
tered.
• The date of the device is out-
side the validity period.
Remote Monitoring Server reply
time-out
The service is not found (invalid
path).
URL setting error
SOAP Client failed to obtain
SOAPResponse. It may be
caused by a problem on the serv-
er side or a temporary problem in
network load, etc.
SOAP error (SOAP Fault)
Device internal error
Internal error at startup of E-RDS Turn OFF and then ON the power of the de-
149
8. Monitoring Function
Remedy
Set the correct date and time on the device.
If the date and time set on the device is cor-
rect, upgrade the version to the latest sys-
tem.
If this occurs during a communication test,
wait for a while and then perform a commu-
nication test (COM-TEST) again.
Check that the value of Remote Monitoring
Server URL (RGW-ADR) is "https://
b01.ugwdevice.net/ugw/agentif010".
NOTE:
If it is for China, check if the URL is
as follows.
https://b01.ugwde-
vice.net.ugw2.canon.com.cn
Check that the value of Remote Monitoring
Server URL (RGW-ADR) is "https://
b01.ugwdevice.net/ugw/agentif010".
NOTE:
If it is for China, check if the URL is
as follows.
https://b01.ugwde-
vice.net.ugw2.canon.com.cn
Perform and complete a communication
test (COM-TEST).
Check that the value of the port number of
Remote Monitoring Server (RGW- PORT) is
443.
Turn OFF and then ON the power of the de-
vice. Or, replace the system software of the
device (version upgrade).
vice.