Download Print this page

Hyundai HYSC75300 Manual page 62

Screw air compressor

Advertisement

Air Dryer
Notice item
A place shall not to be installed.
A place where the storm directly hit and moisture
A place where dusty and corrosive gas
A place a poorly ventilated or confined space
A place where with shake and leaning
A place where there is heat near the input wind
A place where narrow and no maintenance and operations
The temperature should be below 38℃
(B)Installation
A horizontal position does not special installation of foundation
The power distribution should be according to the power、voltage、frequency on
the nameplate
Install a separate power control switch
When two machines put together, it should be keep their distance, it must be to
avoid the hot exhaust of a machine is another inhalation
(C) Stop and run
Stop running the machine, and then start running at least 3-5 minutes later
Low load or low temperature, the machine will stop and run interval. It is normal
Air-cooled (MID -TEMP) air dryer flow diagram
Exit and entrance
Refrigerant pressure meter
Evaporator
Water separator
Expansion valve
Refrigerant filter
Bypass valve
Pressure controller
Drainage
Refrigerant compressor
Condenser fan
Condenser
Air-cooled (MID -TEMP) air dryer type and technical date
Type, Air volume, Use condition
Entrance temp. ≤45℃
Work pressure 0.3-1.0MPa (over pressure, accept custom)
Refrigerant
Other, accept custom
B condition temp.38℃