S h o c k p r o o f
f a s t e n e r s
b) Debugging of the new machine must be operated by appointed or authorized person by the
company.
c)Operators must read, comprehend and follow the relevant operating procedures, announcements
and maintenance specifications in the manual.
d) The air compressor without air storage tin can only be used after being equipped with air storage
tin.
e) The air compressor shall not be arbitrarily altered or set the rated operating voltage to avoid
overload damage to the motor.
f) Air compressor shall be operated indoor, with good ventilation and a temperature that is less than
45℃.
g) The end of the inlet wire of power supply shall be equipped with a terminal to guarantee that the
bolt in the terminal is fixed and won't become flexible. The wire must be installed by professional
electricians( As shown in Picture 11).
h) It is strictly prohibited that the compressor operates under a pressure less than 0.4Mpa in
long-term basis.
i) Keep the lubricating oil between the range of upper and lower limits of the oil indicator. Mixture of
different brands of lubricating oils is strictly prohibited to avoid serious accident caused by coke
accumulation in pipeline system.
j) It is strictly prohibited to examine and repair the electrical equipment and circuit under the condition
that the power supply is not off.
k) It is strictly prohibited to examine and repair the pressure volume and pressure pipeline.
l) Timely get rid of the moisture in gas and oil barrel.
m) The exhaust temperature shall be between 70 and 105℃.
n) Cleansers which are inflammable, explosive and volatile cleaners cannot be used to maintain and
Picture 10.
Picture 11.
The end of the
inlet wire