7. Factory Parameters
The factory parameters can be looked over and modified with manufacturer password, but its
operation method is the same as that of user parameters. Please refer to following table for main
functions and purposes.
PASSWORD :0***
Manufacturers enter the correct password , press set button, switch to the factory
parameters of the interface as follows
MOTOR CURR:
100. 0A
Continuously press "
FAN CURR, PRE-ALARM TEM, STOP TEMP, STOP PRESS, MAX U.L. PRESS,
TOTAL RUN TIME, TOTAL LOAD TIME, RESET FAULT......ect.
Factory parameters "run time", "phase sequence protection," "Frequency
Selection" and the time need check super password to changes.
8. Manufacturers and function
PARAMETER
MOTOR CURR
FAN CURR
ALARM T.
STOP T.
STOP P.
MAX U.L.
9999H
9999H
9999H
9999H
9999H
ENGLISH/C
HINESE
****
*
Move down button
Initial Value
MAXIMUM OVERLOAD
VAULE OF THE MOTOR
/1.2
Maximum allowable fan
motor
overload
value/1.2
105℃
110℃
1.00MPa
0.80MPa
Set this value to "0" to disable the O/G separator
alarm function
Set this value to "0" to disable the alarm function of
gas filter
Set this value to "0" to disable the time alarm of
lub. oil
Set this value to "0" to disable the time alarm of
Lub. Grease
Set this value to "0" to disable the time alarm of
belt.
Set this value to "EN" , Display text in English
Set this value to "CH" , Display text in Chinese
Customer could modify the user password
" you can see factory parameters as follows:
Functions
After the starting delay time, when the motor
current is greater than 1.2 times of the set value
and less than 4 times of the set value, the unit
will jump as per overload feature.
Same as above
Pre-alarm when the temperature reaches this set
value
Alarm when the air exhausting temperature
reaches this set value.
Alarm and stop the machine when the air supply
temperature reaches this set value
The Unload Limit Pressure in the Customer