2. Technical parameters and functions
1、Digital input: Digital input of 3# circuit; digital output of relay of 5# circuit;
2、Simulation quantity: Pt100 temperature input of 1# circuit; 4~20mA input of transducer of 1#
circuit; two groups of three phase current input(CT provided) ;
3、Input voltage of phase sequence: three phase 380V/220V;
4、Controller's power supply: AC20V、50Hz、10VA;
①、Oil temperature:-50~150℃; precision: ±1℃.
5、Measurement range displayed:
②、Air temperature:-50~150℃;precision:±1℃.
③、Operation time: 0~999999 hours.
④、Measurement range displayed for current:0~999.9A.
⑤、Pressure: 0~1.60MPa. Precision: 0.01Mpa.
6、Phase-sequence protection: When protector inspects wrong phase, response time≤2s (optional);
7、 Protection of motor: this controller has five basic protection functions for main motor and fan's
①、 block protection: When working current reaches to from 4 times to 8 times of set current after
motor
②、Short circuit protection: when testing current reaches above 8 times of set current, response
finish starting, response time ≤0.2s;
③、Protection of phase failure: in case of phase failure of any one phase,
time≤0.2s;
④、Unbalance protection: when currents of any two phase differ 60~75%,
setup time;
⑤、Protection characteristics of reverse time limit of overload (time unit: second),please see
set time;
following table(table 2.1.1) ,multiple=I
motor operates with delay time according to overload factors and operation time shown in
following table (table 2.1.1) when motor's working current is larger or equal to from 1.2 times
and 3.0 times of set current.
I
actual
Time parameters
Operation time (S) 60
Table 2.1.1 curve table of reverse time limit for protection of motor
8、Temperature protection: when actual temperature measured is larger than temperature set;
response time≤2s;
9、Contact capacity of output relay: 250V,5A;Contact endurance 500000 times
10、Error of displayed current is less than 1.0%.;
11、RS485 communication
I
/
set
≥1.2
≥1.3
48
"run time " "phase sequence protection " "power
/I
actual
set
≥1.5
24
operation time equals
operation time equals
≥1.6
≥2.0
8
5
≥3.0
1