Advertisement

ELECTRIC AIR COMPRESSOR
Models HY3050, HY30100 & HY3150
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Hyundai HY3050

  • Page 1 ELECTRIC AIR COMPRESSOR Models HY3050, HY30100 & HY3150 User Manual...
  • Page 2: Table Of Contents

    CONTENTS TITLE PAGE No 1. SAFETY 3 – 4 2. UNPACKING – USGAE INSTRUCTIONS 5 – 8 3. PART LOCATIONS 4. SPECIFIC SAFETY 9 – 11 5. OPERATION, MAINTENANCE & TROUBLESHOOTING 12 - 19 6. SPECIFICATION 7. WIRING DIAGRAM 8. GENPOWER CONTACT DETAILS 9.
  • Page 3: Safety

    1. SAFETY. 1.1. The operator of the machine; 1.1.1. Is responsible for and has a duty of care in making sure that the compressor is operated safely and in accordance with the instructions in this user manual. 1.1.2. Should never leave it in a condition which would allow an untrained or unauthorised person/s to operate this compressor.
  • Page 4 1.3. Electrical Safety. 1.3.1. Electricity can kill - never work on LIVE/ENERGISED equipment. 1.3.2. Identify electrical isolation method and always isolate all electrical supplies, prior to carrying out any maintenance work. 1.3.3. Prior to use and with all electrical supplies isolated check all electrical cables, plugs and connections for the following.
  • Page 5: Unpacking - Usgae Instructions

    2. UNPACKING - USAGE INSTRUCTION. PAGE 5 Rev 2...
  • Page 6 Rev 2 PAGE 6...
  • Page 7 AGE 7 Rev 2 � � ��...
  • Page 8: Part Locations

    3. PART LOCATIONS DIRECT COMPRESSED AIR OUTLET. TANK. PRESSURE REDUCER. BELT GUARD. COMRESSOR UNIT. ELECTRIC MOTOR. PRESSURE SWITCH. PRESSURE GUAGE. PIVOT WHEEL. CONDENSATE DRAIN. WHEEL. CHECK VALVE. PAGE 8 Rev 2...
  • Page 9: Specific Safety

    4. SPECIFIC SAFETY Read and understand all of the operating instructions, safety precautions and warnings in the Instruction Manual before operating or maintaining this compressor. Most accidents that result from compressor operation and maintenance are caused by the failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing a potentially hazardous situation before it occurs, and by observing appropriate safety procedures.
  • Page 10 4.12 Maintain compressor with care. Follow instructions for lubricating. Inspect power leads periodically and if damaged, have repaired by authorised service facility. Inspect extension leads periodically and replace if damaged. 4.13 Outdoor extension leads. When compressor in used outdoors, use only extension leads intended for use outdoors and so marked.
  • Page 11 4.26 DO NOT direct the air stream at body. DO NOT direct air stream at persons or animals. There is a risk of injury, by directing air stream at persons or animals. 4.27 Drain tank. Drain tank daily or after 4 hours of use. Open drain fitting and tilt compressor to empty accumulated water.
  • Page 12: Operation, Maintenance & Troubleshooting

    5. OPERATION & MAINTENANCE The information contained in this Instruction Manual is designed to assist you in the safe operation and maintenance of the compressor. Some illustrations in this Instruction Manual may show details or attachments that differ from those on your own compressor. 5.1 Installation.
  • Page 13 Compressors installed on the 500 lt tank, with capacity of HP7.5/ 55 kW and HP10/7.5 kW can be supplied a star/triangle starting control unit, whereas the TANDEM (2 pumping elements on the same tank) are supplied with a timed control unit for staggered starting of the two pumping elements.
  • Page 14 5.7 Tandem compressors with timed control unit. (fig. 17). 5.7.1 Fit the plug in the power socket (fig. 13) and turn the pressure switch to position “I” (ON). Turn the master power switch “A” on the control unit to position I – power On is signalled by white indicator-light “E”...
  • Page 15 5.8 Tandem compressors with timed control unit. (fig. 17). 5.8.1 .1 Fit the plug in the power socket (fig. 13) and turn the pressure switch to position “I” (ON). Turn the master power switch “A” on the control unit to position I – power On is signalled by white indicator-light “E”...
  • Page 16 5.10 Tandem compressors with timed control unit. (fig. 17). 5.10.1 .1 Fit the plug in the power socket (fig. 13) and turn the pressure switch to position “I” (ON). Turn the master power switch “A” on the control unit to position I – power On is signalled by white indicator-light “E”...
  • Page 17 5.11.4 On pressure reducers equipped with a pressure gauge, pressure can be seen on the gauge itself. Some pressure regulators do not have "push to lock", therefore simply turn the knob to adjust the pressure. 5.12 Maintenance. Before attempting any maintenance jobs on the compressor, make sure of the following: Master power switch in position “0”.
  • Page 18 5.13 Oil change table. Type of oil Hours run FIAC oil synthesis ........... 500 Synthetic oil: AGIP Sint 2000 Evolution - BP Visco 5000 ESSO Ultron - MOBIL Mobil 1 NILS Dimension S - NUOVA STILMOIL Arrow5W50 ........... 400 Other types of oil: mineral multigrade; SAE15 W40 ............
  • Page 19 - Temperature in operating ambient: 0°C +35°C. - DO NOT aim jets of water or inflammable liquids on the compressor. - DO NOT place inflammable objects near the compressor. - During down-times, turn the pressure switch to position “0” (OFF). - Never aim the air jet at people or animals (fig.
  • Page 20: Specification

    6. SPECIFICATION HY3150. HY30100. Model HY3050. Voltage - V Number of phases Frequency – Hz 3 pin plug - BS1363A 3 pin plug - BS1363A 3 pin plug - BS1363A Connection method/Cable length m 3/2.25 3/2.25 3/2.25 Motor power hp/kw...
  • Page 21: Genpower Contact Details

    8.3 Email contact; Techinical - service@genpower.co.uk 8.4 Web site; www.hyundaipowerequipment.co.uk 9. DECLARATIONS of CONFORMITY. 9.1 Genpower Ltd confirms that this Hyundai product conform to the following CE directives. 2004/108/EC EMC Directive 2006/42/EC Machinery Directive 2006/95/EC Low Voltage Directive 2009/105/EC Simple Pressure directive...
  • Page 22: Recycling

    RECYCLING Products which are labelled with the adjacent symbol MUST NOT be disposed of in household rubbish. You must dispose of packaging and old electrical and electronic equipment separately. 10.1 Disposing of packaging. 10.1.1 The packaging consists of cardboard and correspondingly marked plastics that can be recycled.
  • Page 23 PAGE 23 Rev 2...
  • Page 24 Isaac Way, London Road Pembroke Dock, UNITED KINGDOM, SA72 4RW T: +44 (0) 1646 687 880 F: +44 (0) 1646 686 198 E: info@hyundaipowerequipment.co.uk www.hyundaipowerequipment.co.uk...

This manual is also suitable for:

Hy30100Hy3150

Table of Contents