Data Exchange - Graco EVR Instructions Manual

Electric variable ratio proportioner
Table of Contents

Advertisement

I/O Integration

Data Exchange

NOTE: For EVR Data Exchange timing diagrams, see F
Command Value
(base 10 decimal)
1
Red MCM Active Alarms bitfield
Red MCM Active Deviations bit-
2
field
3
Red MCM Active Advisories
4
Blue MCM Active Alarms bitfield
Blue MCM Active Deviations bit-
5
field
6
Blue MCM Active Advisories
7
Pump Size A
8
Pump Size B
9
Purge and Base Purge Flow Rate
Pressure Imbalance Alarm
10
Enabled
11
Pressure Imbalance Alarm Level
12
Red Pump Current Cycles❖
13
Blue Pump Current Cycles❖
Dispense Valve is Opened
14
Cycles❖
15
Red Pump Life Time Cycles
16
Blue Pump Life Time Cycles
Dispense Valve is Opened Life
17
Time Cycles
18
Red Pump Limit Cycles
19
Blue Pump Limit Cycles
Dispense Valve is Opened Limit
20
Cycles
21
Recipe Look Up Number
22
Recipe Look Up Shot Size
52
. 26 page 65.
IG
EVR Fieldbus Map 19C930
Data Exchange
Format and
Name
XXXX.XX cc
XXXX.XX cc
XXXX.XX cc
Read/Write
Units
bitfield
Read Only
bitfield
Read Only
bitfield
Read Only
bitfield
Read Only
bitfield
Read Only
bitfield
Read Only
Read/Write
Read/Write
XXXX.XX
Read/Write
cc/sec
Boolean
Read/Write
XXXX.XX
Read/Write
bar
XXXX
Read/Write
cycles
XXXX
Read/Write
cycles
XXXX
Read/Write
cycles
XXXX
Read Only
cycles
XXXX
Read Only
cycles
XXXX
Read Only
cycles
XXXX
Read/Write
cycles
XXXX
Read/Write
cycles
XXXX
Read/Write
cycles
Recipe XX
Read/Write
Read Only
Minimum
Maximum
Value
Value
0
4,294,967,296
0
4,294,967,296
0
4,294,967,296
0
4,294,967,296
0
4,294,967,296
0
4,294,967,296
1.00
160.00
1.00
160.00
0.00
69.33
0
1
0.00
275.79
0
2,147,483,647
0
2,147,483,647
0
2,147,483,647
0
2,147,483,647
0
2,147,483,647
0
2,147,483,647
0
2,147,483,647
0
2,147,483,647
0
2,147,483,647
0
50
0.00
327.68
3A8565C

Advertisement

Table of Contents
loading

Table of Contents