Shutdown; Pressure Relief Procedure - Graco EVR Instructions Manual

Electric variable ratio proportioner
Table of Contents

Advertisement

Shutdown

1. Park the pumps. From the Home screen, press the
icon. Material will dispense. The pump will
park automatically. Once the pump is parked, the
pump will stop moving.
2. Press the enable/disable key on the ADM
disable the EVR.
3. Turn the Power Disconnect Switch (C) to the OFF
position.
4. Relieve fluid pressure from the supply system. See
your appropriate supply system manual for instruc-
tions on relieving fluid pressure.
5. Perform the Pressure Relief Procedure on page
17.

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever
you see this symbol.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop spraying and before clean-
ing, checking, or servicing the equipment.
NOTE: The fittings on the pressure relief hoses are zinc
plated carbon steel. The hoses are cured with sulfur.
Check your materials for compatibility with zinc plating
and sulfur before reusing any material that passed
through them, as it may inhibit curing.
1. Press the enable/disable key on the ADM
disable the EVR, and verify it is inactive.
3A8565C
2. Relieve pressure and shut off the supply systems.
See your appropriate supply system manual.
3. Turn the Outlet Drain/Relief Valves (P, R) to PRES-
SURE RELIEF/CIRCULATION (pointing toward the
drain hoses). Route the fluid to grounded waste
containers or supply tanks. Ensure gauges read 0.
R
to
4. For models with a dispense valve with a safety lock,
engage the dispense valve safety lock.
to