Operation

Operation

Startup

1. Use the supply systems to load the fluid.
NOTE: The EVR is tested with oil at the factory. Flush
out the oil with a compatible solvent before dispensing.
a. Check that all machine connections are tight-
ened. See Setup on page 14.
b. Verify both feed supply systems are connected
to an air supply.
c. Turn the Power Disconnect Switch (C) to the
ON position.
d. Verify the machine is ON and the System Sta-
tus Indicator (AB) is solid green. See System
Status Indicator (AB) Conditions on page 10.
e. Turn both Outlet Drain/Relief Valves (P, R) to
DISPENSE (pointing toward the outlet pressure
gauges).
R
f.
Start the supply systems. See Adjust Material
Inlet Pressure on page 18.
16
Keep Components A and B Separate
Cross-contamination can result in cured material in
fluid lines which could damage equipment or cause
serious injury if injected or splashed on skin or in
eyes. To prevent cross-contamination of the equip-
ment's wetted parts, never interchange component
A and component B parts.
g. Use supply systems to load the system.
h. To prime the pump, cycle the pump a few times
or until air-free fluid dispenses. See Home
Screen on page 32 for instructions on priming
the pump through the ADM.
To prevent serious injury from splashing, dispense
fluids at a low pressure.
i.
Hold the dispense valve nose piece, without a
mixer installed, over two grounded waste con-
P
tainers. Leave the mixer off and trigger the dis-
pense valve until both fluids flow freely from the
nose piece without any air.
j.
With the valve closed, install the required mixer
on the dispense valve. Refer to your dispense
valve manual.
3A8565C