d. Assemble, connect and tighten the component
A (Red) inlet hose to the A Pump Inlet (J).
4. Attach the fluid outlet hoses to the Pump Outlets
(K).
F
. 14
IG
5. Connect the outlet hoses to the dispense valve.
Refer to your dispense valve component manual for
complete installation instructions.
6. Pressure check the hoses. If there are no leaks,
secure the outlet hoses together to protect them
from damage.
3A8565C

Flushing

K
To avoid fire and explosion, always ground equip-
ment and waste container. To avoid static sparking
and injury from splashing, always flush at the lowest
possible pressure.
Flush out old fluid with new fluid, or flush out old
fluid with a compatible solvent before introducing
new fluid.
Use the lowest possible pressure when flushing.
All fluid components are compatible with common
solvents.
To flush the entire system, circulate through the
dispense valve and drain valve.