Graco EVR Instructions Manual page 35

Electric variable ratio proportioner
Table of Contents

Advertisement

Votex Dynamic Mix Valve Run Screen
This screen will only be displayed if the
NOTE:
Voltex Dynamic Mix Valve is connected to the EVR
Network.
12
1
13
0 psi
8
9 11
10
1. System State: Green frame with Active indi-
cated means the system is ready to run.
Amber frame with System Off indicated means
system is off.
2. Motor RPM Setpoint: The RPM's that the
motor will run at. The Motor RPM Setpoint can
be locked requiring a password.
3. Motor Ramp Up Time: This changes the
amount of time in milliseconds the motor takes
to get to the RPM setpoint. NOTE: 100ms is
the fastest acceleration and 9000ms is the
slowest acceleration. The goal is to try and
prevent breaking mixers with a slower acceler-
ation. Example: 500ms = half a second to get
to the RPM setpoint of 4400 RPM.
4. (B) Valve Status: Icon turns green when the
dispensing system turns on the valve signal.
Icon turns gray when dispensing system is off.
5. (B) Valve Pressure: If a pressure transducer
kit is installed, the text will appear on the
screen and display the pressure. There is no
error for the transducer being unplugged.
3A8565C
14
2
3
0 psi
5
4
6
7
6. Manual Motor: This button allows the motor
to be turned on by the ADM at the RPM set-
point.
7. Motor Actual RPM: Shows what speed the
motor is at during the ramp period. It is not
direct feedback from the motor.
8. Air nucleation valve indicator: Icon turns
green if air nucleation is enabled and the valve
is open. Icon turns gray when it is off.
9. Air Purge button: Will open the air nucleation
valve indefinitely to blow out the material in the
mixer
10. (A) Valve Pressure: If a pressure transducer
kit is installed, the text will appear on the
screen and display the pressure. There is no
error for the transducer being unplugged.
11. (A) Valve Status: Turns on when the dispens-
ing system turns on the valve signal.
12. Edit Mode: Select to enter or exit the editing
mode for the screen. Icon is gray when in edit
mode and blue when off.
13. Air Nucleation Disable for Dispensing: Press
this button to stop the air nucleation from run-
ning while dispensing. The icon turns grey to
signal that the air nucleation has been disabled
for dispensing. To re-enable the air nucleation
for dispensing, press the button again. Every
time a dispense occurs with the air nucleation
disabled, an ECAA error will be placed into the
events. See EVR Error Codes starting on
page 25 for more information.
14. Motor Spinning Disable for Dispensing:
Press this button to stop the motor from spin-
ning while dispensing. The icon turns grey to
signal that the motor has been disabled for
dispensing. To re-enable the motor for dis-
pensing, press the button again. Every time a
dispense occurs with the motor disabled, an
ECMA error will be placed into the events. See
EVR Error Codes starting on page 25 for more
information.