Technical Data

XM PFP
Mix Ratio Range
Ratio Tolerance Range (before alarm)
Maximum Flow Rate (measured with oil)
Fluid Viscosity Range
Air Inlet
Fluid Inlets
Maximum Fluid Working Pressure for A and B
Materials
Maximum Fluid Working Pressure for Flushing
Fluid
Maximum Fluid Working Pressure for Heating
Fluid
Maximum Fluid Temperature
System Inlet Supplied Air Pressure Range
Maximum Pump Air Pressure
Maximum Tank Air Pressure
Air Filtration
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Environmental Conditions Rating
Sound Pressure *
Sound Power **
System Weight (empty, no fluid)
Air Consumption
Minimum
Maximum
Typical Application
Power Requirements
Voltage (can be set with jumpers)
Wattage
Amps
3A2989B
US
1:1-10:1 (in 0.01 increments)
+/- 5%
3 gallons per minute
Handles mastic materials which are loaded into heated tanks
with ram-fed priming piston pumps
1 in. npt(f)
Pail (Pail Feed RAM Pumps)
6000 psi
4500 psi
100 psi
160°F
80-150 psi
100 psi
90 psi
40 micron main filter, 5 micron control air filter
32 to 130°F
30 to 160°F
Altitude up to 13,123 ft
86 dBA at 100 psi
98 dBA at 100 psi
2175 lb
100 scfm
250 scfm
125-175 scfm
Option 1: 220-240V, 3 phase DELTA (3 wire plus ground)
Option 2: 380-400V, 3 phase WYE (4 wire including neutral
plus ground)
18,400 watts (23,400 with optional flush water heater)
240V, 3-phase models: 65 Amps per phase full load
380V, 3-phase models: 38 Amps per phase full load
Metric
13.6 liters per minute
41 MPa, 414 bar
31 MPa, 7 bar
0.7 MPa, 7 bar
70°C
0.5-1.0 MPa, 5.5-10.3 bar
0.7 MPa, 7 bar
0.6 MPa, 6 bar
0 to 54°C
-1 to 71°C
Altitude up to 4000 m
86 dBA at 0.7 MPa, 7 bar
98 dBA at 0.7 MPa, 7 bar
987 kg
3
2.8 meter
/min
3
7.1 meter
/min
3
3.5-5.0 meter
/min
Technical Data