Maintenance; Preventative Maintenance Schedule; Check Oil Level - Graco EVR Instructions Manual

Electric variable ratio proportioner
Table of Contents

Advertisement

Maintenance

NOTE: See the Maintenance section in your compo-
nent manuals for maintenance instructions for specific
system components. See Related Manuals on page 2.
Task
Change break-in oil in a new unit
Inspect fluid lines for leaks
Grease Outlet Drain/Relief Valves
®
(R,P) with Fusion
grease
(117773)
Clean dispense valve mix cham-
ber ports regularly, see dispense
valve manual
Clean dispense valve check
valve screens, see dispense
valve manual
Grease Outlet Drain/Relief Valves with
Fusion Grease (117773)
R
3A8565C
Preventative Maintenance
Schedule
The operating conditions of your particular system
Schedule
determine how often maintenance is required. Establish
a preventative maintenance schedule by recording
After first
when and what kind of maintenance is needed, and
200,000 -
then determine a regular schedule for checking your
300,000 cycles
system.
Daily

Check Oil Level

Weekly
Check the oil level in sight glass (FC). (See F
oil level should be near the halfway point of the sight
See dispense
glass when the sprayer is not running. If oil is low, open
valve manual
fill cap (FB) and add Graco Part No. 16W645 ISO 220
silicone-free synthetic EP gear oil. See F
See dispense
The oil capacity is approximately 2.0 - 2.2 quarts (1.9 -
valve manual
2.1 liters). Do not overfill.
Only use oil with Graco part number 16W645. Any
other oil may not lubricate properly and can cause
damage to the drive train.
P
FC
F
IG
NOTICE
FD
. 15: Sight Glass and Oil Fill Cap
Maintenance
. 15.) The
IG
. 15.
IG
FB
19