Setup

Setup
After placing the EVR in the desired area of operation:
NOTE: Make sure the EVR is placed on a level surface.
See Dimensions on page 72 for space requirements.
1. Anchor the EVR to a fixed mounting location. See
Dimensions on page 72.
2. Follow steps a through c to install pumps ordered
separately for EVR systems configured without
pumps. If the EVR is already configured with
pumps, proceed to step 3.
a. Install inlet fittings onto the A and B pumps pur-
chased separately.
b. Install the pumps onto the EVR. Use spring
clamps (provided with pumps) to couple the
pump to yoke adapters.
c. Install adapters into the pump outlets, then
install outlet manifold assemblies and drain
tubes.
d. Remove the plugs installed on the back of the A
and B pumps, and install the pressure
transducers as shown in F
F
. 11
IG
e. Install pressure transducers into port #6 on
both A and B Electric Drivers (G). The A pres-
sure transducer is marked with red tape, and
the B pressure transducer is marked with blue
tape.
14
. 11.
IG
pressure transducer
Port #6
F
. 12: Electric Driver Port #6
IG
3. Connect the supply systems.
a. Install feed pumps for component A (Red) and
B (Blue) supply drums.
inlet pressure
gauge
J
F
. 13
IG
b. Ensure the supply systems and, if applicable,
the inlet regulators are off or set to zero pres-
sure before connecting.
NOTE: Supply hoses from feed pumps should be 3/4
in. (19 mm) ID minimum.
c. Assemble, connect and tighten the component
B (Blue) inlet hose to the B Pump Inlet (J).
J
2000 psi max
3A8565C