Graco EVR Instructions Manual page 54

Electric variable ratio proportioner
Table of Contents

Advertisement

I/O Integration
Command Value
(base 10 decimal)
40
Red Tank Sensor Configuration
Blue Tank Stand Active Alarms
41
Bitfield
Blue Tank Stand Active Deviations
42
Bitfield
Blue Tank Stand Active Advisories
43
Bitfield
44
Blue Tank Stand Refill Timeout
45
Blue Tank Stand Refill Timeout
46
Blue Tank Sensor Configuration
47
Recirculation Mode
48
Recirculation Flow rate
49
Recirculation Timer on Time
50
Recirculation Timer off Time
51
Recirculation Timer Remaining
Park Using Recirculation valves
52
Enable
54
EVR Fieldbus Map 19C930
Data Exchange
Format and
Name
1-Low and
High Sensor
2-Low and
Mid Sensor
High Sensor
4-Low, Mid,
1-Low and
High Sensor
2-Low and
Mid Sensor
High Sensor
4-Low, Mid,
Read/Write
Units
Installed
Installed
3-Mid and
Read/Write
Installed
and High
Sensor
Installed
Bitfield
Read Only
Bitfield
Read Only
Bitfield
Read Only
0-Disable
1-Monitor
Only
Read/Write
2- manual
Fill
Minutes
Read/Write
Installed
Installed
3-Mid and
Read/Write
Installed
and High
Sensor
Installed
0-Disable
1-Manual
Read/Write
2-Timer
XXXX.XX
Read/Write
cc/sec
Minutes
Read/Write
Minutes
Read/Write
sec
Read Only
0-Disable
Read/Write
1-Enabled
Minimum
Maximum
Value
Value
1
4
0
4, 294,967,296
0
4, 294,967,296
0
4, 294,967,296
0
3
0
99
1
4
0
2
0
69.33
0
420
0
420
0
25,200
0
1
3A8565C