Troubleshooting
Error
Code
Type
CAT_
Advisory
CAVX
Advisory
CACX
Advisory
CCCX
Advisory
Record
ECAA
Only
Record
ECMA
Only
F3N_
Advisory
F4CX
Alarm
F4RX
Alarm
F4PX
Alarm
26
Code Description
Comm. Error _____
Tank Stand
Comm. Error Voltex
DMV
Comm. Error Gateway
Comm. Error Gateway _
Air Nucleation Disabled
for Dispense
Motor Spinning
Disabled for Dispense
Unable to Maintain Flow
Rate _
Recirculation Flow
Exceeds Max Flow
Recipe Flow Exceeds
Max Flow
Purge Flow Exceeds
Max Flow
Cause
System unable to
communicate with tank
stand
System is unable to
commu8nicate with Voltex
dynamic mix valve (DMV)
Motor Control Module
(3MCP) lost communication
with automation controller
Motor Control Module
(3MCP) lost communication
with automation controller
The air nucleation dispense
button was pressed on the
home run screen and a
dispense occurred
The air nucleation dispense
button was pressed on the
home run screen and a
dispense occurred
Pump is unable to deliver
the desired flow rate
The flow rate requested by
the recirculation exceeded
the max flow rate (26 cycle
per pump)
The flow rate requested by
the recipe exceeded the
max flow rate (26 cycle per
pump)
The flow rate requested by
the purge exceeded the max
flow rate (26 cycle per
pump)
Solution
Verify CAN cable is plugged in
Remove and reconnect CAN
cable, taking care not to cross
thread the connector nut
Verify CAN cable is plugged in
Remove and reconnect CAN
cable, taking care not to cross
thread the connector nut
Verify fieldbus cable is properly
connected
Verify host is communicating
Verify fieldbus cable is properly
connected.
Verify host is communicating.
No action necessary if desired. If
not desired, press the button on
the run screen again to enable
the air nucleation during
dispensing
No action necessary if desired. If
not desired, press the button on
the run screen again to enable
the motor during dispensing
Reduce flow rate.
Increase pump sizes.
Measure line voltage. Low line
voltage may reduce maximum
operating flow rate.
Reduce the flow rate so that the
recirculation flow rate is below
the max flow rate
Reduce the flow rate so that the
recipe flow rate is below the max
flow rate
Reduce the flow rate so that the
purge flow rate is below the max
flow rate
3A8565C