Troubleshooting
Error
Code
Type
P9D_
Alarm
P9F_
Advisory
T4N_
Alarm
V1N_
Alarm
V4N_
Alarm
WBN_
Alarm
WMN_
Alarm
W5N_
Deviation
WSNX
Alarm
WVCX
Deviation
30
Code Description
High Pressure Outlet _
High Pressure Inlet _
High Temperature
Motor _
Low Voltage Motor _
High Voltage Motor _
Encoder Error Motor
Controller Fault Motor
Encoder Calibration
Motor
Invalid Recipe
Motor Fault
Cause
Pressure exceeds system
limit
Pump are moving as a result
of high inlet pressure
Cooling fans not working
properly
AC voltage is too low
AC voltage is too high
Encoder not plugged in
Faulty encoder
Faulty circuit board
Encoder not calibrated
Entry into recipe is not
correct or zero
Over Torque
No power to motor
Solution
Inspect for hardened material or
obstructions to flow.
Attempt to purge material at a
reduced flow rate.
Reduce operating pressure by
reducing flow rate and/or restric-
tion in the hose and valve.
Turn down the inlet pressure on
the feed pump.
Ensure cooling fans are clear of
obstructions and operating prop-
erly.
Check wire connections and ver-
ify line voltage is within specifica-
tion.
Verify line voltage is within speci-
fication.
Ensure encoder connector is fully
plugged into the circuit board
inside the driver.
Replace encoder.
Replace motor control circuit
board.
Calibrate the Encoder from the
maintenance screen of the
Advanced Display Module
(ADM).
Enter a valid value
Cycle power. Increase ramp up
time. Cycle power to unit
Clean mixer. Cycle power to unit
Make sure that motor has power.
Check power supply if cycle
power is needed