Baling Press Malfunctions; Error Numbers - HSM SP 5080 Operating Manual

Shredder and baling press combination
Hide thumbs Also See for SP 5080:
Table of Contents

Advertisement

4.6

Baling press malfunctions

As soon as a malfunction occurs in the baling press, the red malfunction symbol
Switch off the baling press and shredder and an error message appears in the text display.
The "Baling press operating state" symbol
The previous error message is saved in the error memory.
By pressing the +/– button at the same time or switching on and off, the system can delete
various error messages displayed.
Service hotline: +49 75 54 2100 300
4.6.1

Error numbers

Code
Description
100
Communication PIC <-> ATMEL
101
Contactor defective
102
Motor protection has been triggered.
103
Press cylinder feedback
104
Hydraulic locking mechanism feedback
105
Hydraulic channel adjustment feedback
106
Press timeout
107
Reversed rotation
108
Phase fault
109
EEPROM CRC fault
110
Pressure switch defective
111
Excess hydraulic oil temperature
112
Open/ruptured hydraulic oil temperature sensor
113
Short circuit in hydraulic oil temperature sensor
114
Door switch defective
115
Channel switch not seen
116
Maximum motor runtime achieved
117
Light barrier interrupted
118
Shearing fault
119
UPPER proximity switch defective, only KP40
120
LOWER proximity switch defective, only KP40
121
FRONT proximity switch defective
122
REAR proximity switch defective
123
Oil cooler contactor does not tighten
44
on the shredder lights up red.
Remedy
Electrician! Call HSM Service!
Electrician! Call HSM Service!
Electrician! Call HSM Service!
Electrician! Possible cable rupture or defective sole-
noid valve!
Electrician! Possible cable rupture or defective sole-
noid valve!
Electrician! Possible cable rupture or defective
solenoid valve!
Call HSM Service!
Phase is reversed Electrician! Replace phase!
Electrician! Phase missing
Electrician! Call HSM Service!
Electrician! Call HSM Service!
Let motor cool down - wait approx. 20 minutes
Electrician! Call HSM Service!
Electrician! Call HSM Service!
Electrician! Call HSM Service!
Electrician! Call HSM Service!
Switch off for 5 minutes and wait! Call HSM Service!
Remove material bridge / clean light barrier
Remove material jam
Electrician! Call HSM Service!
Electrician! Call HSM Service!
Electrician! Call HSM Service!
Electrician! Call HSM Service!
Electrician! Call HSM Service!
2.993.999.520_en