A.3 Power Ratings
Feature
Minimum
supply voltage
Nominal
supply voltage
Maximum
supply voltage
Maximum continuous
power output
Efficiency at
rated power (at nominal
conditions)
Maximum output voltage
Auxiliary supply voltage
Auxiliary power supply
Amplitude sinusoidal/DC
continuous current
Sinusoidal continuous RMS
current limit (Ic)
Peak current limit
Output power without
additional heatsink
Weight
Dimensions
Digital in/Digital
out/Analog in
Mounting method
A.4 Environmental Conditions
Feature
Ambient operating temperature
Storage temperature
Maximum humidity
Protection level
Units
VDC
10
VDC
50
VDC
59
W
240 480 720 1000 1440
%
VDC
VA
A
5
10
15
A
3.5 7.1 10.6 15 21.2 2.3 7.1
A
%
100
g (oz)
mm
(in)
Technical Specifications
20
85
95
800
260
1200
> 97
97% of DC bus voltage at f=22 kHz
24 ± 20%
12
21
30
3.3 10 15
10.6
2 x Ic
7
100
5
640 g (22.6 ounces)
150 x 25.4 x 105 (5.9" x 1.0" x 4.1")
10/5/2
Wall mount (on back or on side)
Details
0 °C – 40 °C (32 °F – 104 °F)
-20 °C – 85 °C (-4 °F – +185 °F)
90% non-condensing
IP20
40
170
195
360 960 1600 2400 3400
1700 2400
21
30 2.25
6
15 21.2 1.6
4.2
100
A-4
10
15
21
7.1 10.6
15
75
50