A.1
Features
A.1.1
Motion Control Modes
• Current/Torque - up to 14 kHz sampling rate
• Velocity - up to 7 kHz sampling rate
• Position - up to 3.5 kHz sampling rate
A.1.2
Advanced Positioning Motion Control Modes
• PTP, PT, PVT, ECAM, Follower, Pulse and Direction, Dual Loop
• Fast event capturing inputs
• Fast output compare (OC)
A.1.3
Advanced Filters and Gain Scheduling
• "On-the-Fly" gain scheduling of current and velocity
• Velocity and position with "1-2-4" PIP controllers
• Automatic commutation alignment
• Automatic motor phase sequencing
A.1.4
Fully Programmable
• Third generation programming structure with motion commands
• Event capturing interrupts
• Event triggered programming
A.1.5
Feedback Options
• Incremental Encoder – up to 20 Mega-Counts (5 Mega-Pulse) per
second
• Digital Halls – up to 2 kHz
• Incremental Encoder with Digital Halls for commutation – up to 20
Mega-Counts per second for encoder
• Absolute Encoder
• Interpolated Analog Sine/Cosine Encoder – up to 250 kHz (analog
signal)
• Resolver
• Elmo drives provide supply voltage for all the feedback options
• Tachometer, Potentiometer
Internal Interpolation - up to x4096
Automatic Correction of amplitude mismatch, phase
mismatch, signals offset
Encoder outputs, buffered, differential.
Programmable 10~15 bit resolution
Up to 512 revolutions per second (RPS)
Encoder outputs, buffered, differential
A-1