4.7 Possible uses of onboard drive and measuring system interface in the application (C230-2, C240)
Use as counter input on X3 to X6
An available encoder input of an axis channel (e.g. for a speed-controlled axis) can be used as
an input for a 16-bit up/down counter (90-degree pulse train of a connected TTL encoder, zero
pulse not required). The counter value can be accessed by means of an I/O variable.
Configuration procedure in SIMOTION SCOUT:
1. Specification of start address in the hardware configuration.
2. Use of the available encoder input as an additional counter using an incremental encoder.