Addressing

7.3 Addressing signal modules

In the case of input/output modules, the input addresses and output addresses start from the
same module start address.
Table 7-1
Module start addresses of signal modules
Module carri‐
Module start ad‐
er
dresses
0
Digital
Analog
1
Digital
Analog
The FM and CP modules are assigned to the analog address range.
1)
Note
Do not insert any non-configured modules centrally. Modules that are installed but not
configured are repeatedly addressed via the I/O bus. This requires additional computing time.
7.2
User-assignable addressing on the SIMOTION C (centralized and
distributed I/O)
User-assignable addressing
User-assignable addressing means you can assign an address of your choice to each module or
slot, for example, integrated inputs/outputs, drives. You make this assignment in the hardware
configuration (see SIMOTION SCOUT online help). Here you specify the module start address on
which all further module addresses will then be based.
advantages
Advantages of user-definable addressing:
• You can make the best possible use of the available address spaces because there are no
"address gaps" between the modules.
• When creating standard software, you can specify addresses which are independent of the
respective configuration of the SIMOTION modules.
7.3
Addressing signal modules
Introduction
The following section describes signal module addressing in the default setting. You need the
information so that you can address the signal module channels in the user program.
130
1
2
PS
SIMOTION C
1)
-
-
1)
Slot number
3
4
5
IM 365 S
0
4
256
272
IM 365 R
32
36
384
400
Operating Instructions, 11/2022, A5E33441428B
6
7
8
9
8
12
16
20
288
304
320
336
40
44
48
52
416
432
448
464
10
11
24
28
352
368
56
60
480
496
SIMOTION C