Addressing

7.5 Addressing the onboard drive and measuring system interface of the C230-2, C240

7.4
Addressing the onboard digital inputs and outputs of the
SIMOTION C
The following figure shows the default start addresses of the onboard digital inputs/outputs.
Figure 7-6
Note
These addresses can be modified by the user in the hardware configuration (see SIMOTION
SCOUT online help).
When used by a TO (e.g. measuring input/output cam), the address must be ≥ 64.
All start addresses/signal bits (64.4...64.7, 65.0...65.3, 65.6, 65.7, 67.4...67.7) not listed do not
have any defined values and consequently may not be used for evaluation.
As of SIMOTION V4.2, the onboard digital inputs/outputs of the C240 and C240 PN cannot only
be interconnected with variables via their direct addresses, by also by means of symbolic
assignment.
7.5
Addressing the onboard drive and measuring system interface of
the C230-2, C240
Use as a standard output is only possible by means of an I/O variable. The I/O variables must be
created on the addresses of the corresponding axis channel specified via the hardware
configuration (relating to the default start address).
134
Addressing the onboard digital inputs/outputs
Operating Instructions, 11/2022, A5E33441428B