Code
Priority
0x10208
Warning
0x10300
Warning
0x10302
Warning
0x10303
Warning
0x10305
Warning
0x10306
Warning
0x10307
Warning
0x10308
Warning
0x10309
Warning
0x1030A
Error
0x1030B
0x1030C
Warning
0x1030D
Warning
0x10341
Warning
Notification Message
BDU Web UI
All PoE ports except
PoE disabled on
port 1 are shut
LAN2,3,4 due to
down due to high
high temp.
temperature.
Updating software.
Updating software.
Preparing the soft-
Preparing the soft-
ware update.
ware update.
Unable to open the
file for software up-
date.
Unable to down-
grade the software.
The file for software
update does not
support this prod-
uct.
The file for software
update is corrupted.
Software update is
failed.
The software has
been rolled back to
the previous version
due to the validation
failed.
The software up-
date is already run-
ning.
The software trying
to be installed is the
same as the current
running software.
LAN port(s) is/are
running as Half Du-
plex mode.
APPENDIX 3 NOTIFICATION MESSAGES
Explanation/Remedy
Handset
The temperature in the Com-
munication Unit is too high.
All PoE ports except port 1
are shutdown to reduce the
temperature. Move the Com-
munication Unit to a cooler
location, or avoid using the
PoE on LAN2 to LAN4.
System software update in
progress. Wait for the com-
pletion of update.
The system is preparing the
software update. Wait for the
completion of update.
-
The system cannot find the
update file. Confirm that the
update file is saved correctly.
-
Software downgrade is not
allowed. Use the update file
for newer software version.
-
The file for software update
does not support this prod-
uct. Use an appropriate file.
-
The file for software update is
corrupted. Get the file again
from an original source.
-
Software update failed. Retry
the software update.
-
The software has been rolled
back to the previous version
because the validation failed.
Retry the software update.
-
Other software update pro-
gram is running. Retry the
software update after the cur-
rent update program is com-
pleted.
-
The software trying to be in-
stalled is the same as the
current running software.
Use the update file for the lat-
est version.
-
LAN port(s) is/are running as
Half Duplex mode. Half Du-
plex mode is not guaranteed
to work correctly. Configure
the device(s) connected to
the Communication Unit with
Full Duplex mode.