Technical Data

10. Technical Data

10.1 Factory settings

Parameters
Insulation response value R
Insulation response value R
Fault memory insulation measure-
ment
Relay K1 (11/12/14)
Relay K2 (21/22/24)
Relay K3 (31/32/34)
EDS mode
PGH current
Reset to factory settings
BMS address
BMS termination
CAN termination
Permissible system leakage capa-
citance
Measurement speed
Time

10.2 Tabular data isoPV1685...

( )* = factory settings
Insulation coordination acc. to IEC 60664-1 IEC 60664-3
Insulation coordination according to IEC 60664-1
Rated voltage............................................................................................................................................................... DC 1500 V
Rated impulse voltage/pollution degree...........................................................................................................................8 kV/2
Voltage ranges
Nominal system voltage U
Nominal system voltage U
Nominal frequency range with AC coupling ..................................................................................................50/60 Hz +/-1 Hz
Tolerance of U
....................................................................................................................................... AC + 10 %; DC +6 %
n
Supply voltage U
(see also device nameplate) ...................................................................................................... DC 18...30 V
s
Power consumption ......................................................................................................................................................... ≤ 7 W
isoPV1685xxx_D00007_08_M_XXEN/03.2023
an1
an2
N/C operation
N/C operation
N/C operation
isoPV1685RTU ....................................................................................... AC 1000 V, DC 0...1500 V
n
isoPV1685P................................................................................................................DC 0...1500 V
n
Value
isoPV1685P:
Status
can be set via
10 kΩ
1 kΩ
off
auto
30 mA
---
2
ON
RS-485 Term.
OFF
CAN1, CAN2
500 µF
Fast
not defined
isoPV1685RTU:
can be set via
BMS, CAN
BMS, Modbus, CAN
BMS, CAN
BMS, Modbus, CAN
BMS
BMS, Modbus
BMS
BMS, Modbus
BMS
BMS, Modbus
BMS
BMS
BMS
BMS, Modbus
SS8103
SS8103
SS8103
CAN
BMS, Modbus
SS8103
SS8103
SS8103
SS8103