Insulation monitoring device for it ac systems with galvanically connected rectifiers and inverters and for it dc systems specific to railway applications (62 pages)
Insulation monitoring device with integrated locating current injector for it ac systems with galvanically connected rectifiers and inverters and for it dc systems (87 pages)
Insulation monitoring device for unearthed ac, ac/dc and dc systems (it systems) up to 3(n)ac, ac 400 v, dc 400 v suitable for use in applications using generators according to din vde 0100-551 (48 pages)
Insulation monitoring device for unearthed ac, ac/dc and dc systems (it systems) up to 3(n)ac, ac 400 v, dc 400 v (9 pages)
Summary of Contents for Bender ISOMETER isoRW425
Page 1
ISOMETER® isoRW425 Insulation monitoring device for unearthed IT AC-, AC/DC and DC systems (IT systems) for railway applications up to 3(N)AC, AC/DC 440 V Software version: D0418 V2.xx isoRW425_D00052_04_Q_XXEN / 03.2019 Quickstart EN...
Page 2
ISOMETER® isoRW425 Information! Read the corresponding manual in addition to this quickstart. Downloadable at: www.bender.de/en/service-support/downloads Type of device Version Manual No. Art. No. isoRW425-D4W-4 Push-wire terminal D00052 B71037000W isoRW425-D4W-4 Screw-type terminal D00052 B91037000W Mounting clip for screw fixing B98060008 (1 piece per device) Intended use The ISOMETER®...
ISOMETER® isoRW425 Wiring diagram legend Terminal Connections A1, A2 Connection to the supply voltage U via a fuse: If supplied from an IT system, both lines have to be protected by a fuse.* E, E, KE Connect each terminal separately to PE: The same wire cross section as for „A1“, „A2“...
Menu overview Messwertanzeige Standardanzeige Menüauswahl Menü Enter oder t > 5 Min. R [k ] Enter C [µF] U L1 L2 [ V] Parameterauswahl UL1 [ V] UL2 [ V] R [ %] . . . U R [k ] Enter Optionales Passwort Funktion...
ISOMETER® isoRW425 Display elements Device front/display Function green - On yellow - alarm yellow - alarm ON AL1 AL2 Up button Test button (press > 1.5 s) Down button R MENU Reset button (press > 1.5 s) ENTER MENU MENU button (press > 1.5 s) U: Nominal system voltage U R: InsuIation resistance R C: System leakage capacitance C...
Technical data ()* = Factory settings Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated voltage ....................................440 V Overvoltage category....................................III Supply voltage Supply voltage U .............................AC 100…240 V/DC 24…240 V Tolerance of U ..................................-30…+15 % Frequency range U ..................................47…63 Hz Power consumption................................≤...