8.3 Error codes BMS and CAN bus
The following list contains all relevant error codes output via BMS bus or
hand column describes the relevant action to be taken in each case.
Error code
BMS
0
1 .
0
0
0.0
0x2008
8.11
0x8003
8.12
0x8007
8.21
0x8004
8.31
0x8007
8.32
0x8007
8.41
0x8005
8.42
0x8007
8.43
0x8007
8.44
0x8007
8.45
0x8007
8.46
0x8007
9
6 .
1
0
9.62
0x8006
9.63
0x8006
9.64
0x8008
9.71
0x80FF
9.72
0x80FF
9.73
0x80FF
9.74
0x80FF
9.75
0x80FF
9.76
0x80FF
9.77
0x80FF
9.78
0x80FF
9
7 .
9
0
8.4 RS-485 interface with Modbus protocol
Modbus is an internationally widely used protocol for data transfer between devices.
All measured values, messages and parameters are stored in virtual register addresses. Data
can be read out with a read command on a register address. With a write command, data
can be written into a register address.
The register addresses of the individual measured values and parameters can be found in
the "isoxx1685Dx_D00272_00_A_XXDE" manual with the title "ISOMETER® isoxx1685Dx
device family - Modbus settings" at
area/.
40
CAN
Component
Description
x
2
0
4
0
Connection
CT connection
Hardware
Connection to earth (E/KE)
Hardware
Self test insulation monitoring
Hardware
Measuring voltage source
Hardware
Self test residual current monitoring
Hardware
PGH: Locating current too high
Hardware
PGH: Locating current isn't to switch out
&RQQHFWLRQ
Mains voltage (L+, L-) polarity incorrect
Hardware
Supply voltage ADC
Hardware
Supply voltage +12 V
Hardware
Supply voltage -12 V
Hardware
Supply voltage +5 V
Hardware
Supply voltage +3,3 V
x
8
0
0
6
P
a
a r
m
t e
r e
Insulation resistance measurement
Parameter
Residual current measurement
Parameter
Locating current injector
Parameter
Voltage measurement
System
Program sequence insulation monitoring
System
Program sequence residual current measurement
System
Program sequence locating current injector
System
Program sequence voltage measurement
System
Program sequence temperature measurement
System
Program sequence history memory
System
Program sequence console
System
Program sequence self test
x
8
0
F
F
S
s y
e t
m
Stack error
https://www.bender.de/en/service-support/download-
Error
isoPV1685xxx_D00007_08_M_XXEN/03.2023
Device communication
. The right-
CAN bus
To do
Check connection
Check connection
Contact service
Replace the device
Contact service
Replace the device
Replace the device
Check connection
Replace the device
Replace the device
Replace the device
Replace the device
Replace the device
Download factory setting
and parameterise new
Download factory setting
and parameterise new
Download factory setting
and parameterise new
Contact service
Re-start device
Re-start device
Re-start device
Re-start device
Re-start device
Re-start device
Re-start device
Re-start device
Re-start device
Need help?
Do you have a question about the ISOMETER isoPV1685RTU and is the answer not in the manual?