JUKI LZ-2290C-F Instruction Manual page 122

Table of Contents

Advertisement

Error
Description of error
code
E811
Over-voltage
E813
Low voltage
E815
Regenerative resistor is
not connected
E900
Main shaft motor IPM
overcurrent protection
E901
Main shaft motor IPM
overload
E903
85-V power supply fault
E904
24-V power supply fault
E910
The presser motor origin
retrieval error
E912
Main shaft motor speed
detection error
E915
Operation panel commu-
nication error
E916
MAIN-SUB communica-
tion error
E918
Main shaft temperature
error
E922
Main shaft control failure • In the case the main shaft motor is out
E924
Motor driver fault
E946
Machine-head EEPROM
write error
E955
Electric current sensor
error
E961
Pitch motor deviation
error
Cause
• In the case a voltage that is equal to or
more than the guaranteed voltage is
input.
• In the case a voltage of 200 V is applied
though the voltage is set to 100 V.
• In the case a voltage of 220 V is input to
the box of "JA: 120 V".
• In the case a voltage of 400 V is applied
to the box of "CE: 230 V".
• In the case the regenerative resistor is
not connected.
• Maloperation of the main shaft motor.
• In the case the 85-V voltage is not prop-
erly output.
• In the case the 24-V voltage is not prop-
erly output.
• In the case the presser motor has failed
to return to its origin.
• In the case communication with the
operation panel cannot be carried out.
• In the case communication between the
MAIN PCB and the SUB PCB cannot be
carried out.
• In the case the temperature of the CTL
PCB is excessively high.
of control.
• In the case the motor driver has broken.
• In the case the machine head PCB is
not correctly connected.
• Main motor shaft failure.
• Electric current sensor failure.
• In the case the pitch motor fails to oper-
ate because of an excessive load.
– 117 –
Item to be checked
• Check whether the supply voltage of
"rated supply voltage ±10 % or more"
is applied.
In the case the supply voltage exceeds
the aforementioned "rating ±10 %" or
more, the power PCB may have bro-
ken.
• Check whether the regenerative
resister is connected to the regenera-
tive resistor connector (CN11).
• Check whether the stepping motor is
faulty.
• Check whether or not the solenoid
valve is defective.
• Check the F2 fuse.
• Check whether or not the cooling fan
is defective.
• Check the F1 fuse.
• Check whether the presser setting is
correct (memory switch No. 23).
• Check whether the presser motor
origin has been correctly adjusted.
• Check whether CN32 has loosened
or come off.
• Check whether the main shaft motor
has short-circuited.
• Check whether the pitch motor runs
smoothly.