Wiring
Wiring method for three-phase power supply (for all series)
3
Note:
MCCB: molded case circuit breaker
MC: magnetic contactor
SPD: surge protection device
Power 1: power on
Power 2: power off
ALRM_RY: alarm relay
ALRM_RY_A: normally open contact
of the alarm relay
Note: wire with the actual DO parameters of each model.
3-10
T
S
R
MCCB
Noise filter
Power 1
MC
MC
Power 2
MC
ALRM_RY_A
SPD
Servo drive
R
S
T
L
1C
L
2C
P1
P2
U
Motor
V
W
CN1
DO+
ALRM_RY
DO-
ASDA-A3
24 V
DC