GE PACSystems RSTi Manual page 54

Hide thumbs Also See for PACSystems RSTi:
Table of Contents

Advertisement

1
Command
Hex
00000001
01 11
00010001
00000000
00 05
00000101
00000000
00 15
00010101
00000001
01 05
00000101
00000001
01 15
00010101
00000000
00 09
00001001
00000000
00 19
00011001
00000001
01 09
00001001
00000001
01 19
00011001
00000000
00 02
00000010
00000000
00 12
00010010
00000001
01 02
00000010
00000001
01 12
00010010
00000000
00 06
00000110
00000000
00 16
00010110
00000001
01 06
00000110
00000001
01 16
00010110
00000000
00 0A
00001010
00000000
00 1A
00011010
00000001
01 0A
00001010
00000001
01 1A
00011010
DPV1 Read service
Chapter
1-40
Chapter
Reaction to
Bus Fault
Binary
01: Clear Input
data
01: Clear Input
data
01: Clear Input
data
01: Clear Input
data
01: Clear Input
data
01: Clear Input
data
01: Clear Input
data
01: Clear Input
data
01: Clear Input
data
10: Stay with last
input
10: Stay with last
input
10: Stay with last
input
10: Stay with last
input
10: Stay with last
input
10: Stay with last
input
10: Stay with last
input
10: Stay with last
input
10: Stay with last
input
10: Stay with last
input
10: Stay with last
input
10: Stay with last
input
Slot#=0, Index 1: Read STXPBS001 extension parameters (2Byte)
Slot#1~32, Index 1: Read parameter for an IO module.
Slot#1~32, Index 2: Read memory data from an IO module.
Slot#=0, Index 254: Read vendor code from EEPROM directly.
RSTi Network Adapter Manual User Manual - January 2012
DP Clear Action
Word data
Format
00: Bus Stop IO
fault action
01:MOTOROLA
01: Bus Run (
clear Output)
00:INTEL
01: Bus Run (
clear Output)
00:INTEL
01: Bus Run (
clear Output)
01:MOTOROLA
01: Bus Run (
clear Output)
01:MOTOROLA
10: Bus Run (
Hold Output)
00:INTEL
10: Bus Run (
Hold Output)
00:INTEL
10: Bus Run (
Hold Output)
01:MOTOROLA
10: Bus Run (
Hold Output)
01:MOTOROLA
00: Bus Stop IO
fault action
00:INTEL
00: Bus Stop IO
fault action
00:INTEL
00: Bus Stop IO
fault action
01:MOTOROLA
00: Bus Stop IO
fault action
01:MOTOROLA
01: Bus Run (
clear Output)
00:INTEL
01: Bus Run (
clear Output)
00:INTEL
01: Bus Run (
clear Output)
01:MOTOROLA
01: Bus Run (
clear Output)
01:MOTOROLA
10: Bus Run (
Hold Output)
00:INTEL
10: Bus Run (
Hold Output)
00:INTEL
10: Bus Run (
Hold Output)
01:MOTOROLA
10: Bus Run (
Hold Output)
01:MOTOROLA
Restart on Bus
fault
01: auto reset
00:Power reset
01: auto reset
00:Power reset
01: auto reset
00:Power reset
01: auto reset
00:Power reset
01: auto reset
00:Power reset
01: auto reset
00:Power reset
01: auto reset
00:Power reset
01: auto reset
00:Power reset
01: auto reset
00:Power reset
01: auto reset
00:Power reset
01: auto reset
GFK-2746

Advertisement

Table of Contents
loading

Table of Contents