Procedure: Replace The Collector Filter Module In The Ons 15201 Scu; Figure 14-4 Ons 15201 Scu Front Panel - Cisco ONS 15200 Handbook

Table of Contents

Advertisement

Chapter 14
Collector Filter Module

Figure 14-4 ONS 15201 SCU front panel

Remove the four retaining screws from the CFM.
Step 7
Disconnect the CFM optical connectors one at a time and put dust caps on them.
Step 8
Caution
Carefully lift and remove the CFM from the ONS 15201 SCU.
Step 9
Replace the cover (if you do not plan to replace the CFM in the near future).
Step 10

Procedure: Replace the Collector Filter Module in the ONS 15201 SCU

Be careful not to bend the MU cables excessively during this procedure.
Caution
On the front panel of the ONS 15201 SCU, remove the blind plugs on the inside of the SC/SC adapters.
Step 1
Make sure that the ribbon cable from the backplane lies flat on the bottom of the SCU and that it is
Step 2
stretched forward as much as possible.
78-13767-01
CLIP MODULE
Always put dust plugs on the adapters where the connectors were previously installed.
MU CONNECTORS
Cisco ONS 15200 Module Handbook
Removing and Replacing a CFM
PS 1
CFM MODULE
(LOCATED UNDER COVER)
A
B
PS 2
SC CONNECTORS
LEGEND
CFM - Collector Filter Module
CLIP - Client Line Interface Port module
MU - Optical fiber connector type
PS 1 - Power Supply One
PS 2 - Power Supply Two
14-7