Chapter 3 Configuration

Local Control Module Configuration Procedure

Introduction

The LCM needs to know the node's hardware configuration (number of receivers,
transmitters, power supplies, and AC lines mounted or connected) so that it can
control the node's behavior correctly. If an LCM was mounted in the node at
manufacture, then it should be configured correctly as shipped. The configuration
data is stored in an EEPROM residing on the LCM main board.
The LCM includes a craft port module that plugs into the LCM main board. The
craft module contains a local control (craft) port that can be used to configure the
LCM using a handheld programming terminal. This allows access to the LCM menu
only, which provides direct access to the node's configuration.

LCM Configuration Parameters

The following table describes the available LCM configuration parameters when
using a handheld programming terminal with terminal application
"Node_GS7K.app", software number 538888 loaded.
Menu Item Configuration Parameter
0
18
RX Status, RO
RX1 Status, RO
RX2 Status, RO
RX3 Status, RO
RX4 Status, RO
RX1 Power Switch
RX2 Power Switch
RX3 Power Switch
RX4 Power Switch
RFInSwitch to TP
Description/Values
Description: Read-Only status indication.
Indicates status of receivers 1 through 4, and
each receiver's power switch status.
Values: Active, Not Active