Table 4-6 Dwdm Laser Temperature Deviation; Table 4-7 Dwdm Laser Bias Current; Table 4-8 Client Laser Bias Current; Table 4-9 Clip Operating Conditions - Cisco ONS 15200 Handbook

Table of Contents

Advertisement

Technical Specifications
Table 4-6
Threshold
High alarm
High warning
Low warning
Low alarm
Table 4-7
Threshold
High alarm
High warning
Low warning
Low alarm
Table 4-8
Threshold
High alarm
High warning 200%
Low warning
Low alarm
Table 4-9
Item
Normal operating temperature
Short term operating temperature
for equipment shelves
(per GR-63, NEBS level 3)
Rate of temperature change
Normal operating relative humidity
Short term operating relative humidity
(per GR-63, NEBS level 3)
Cisco ONS 15200 Module Handbook
4-8
DWDM Laser Temperature Deviation
Degrees Celsius
+2.5
+1.0
–1.0
–2.5
DWDM Laser Bias Current
Percentage of
calibration current
200%
150%
70%
40%
Client Laser Bias Current
Percentage of
calibration current
300%
50%
20%
CLIP Operating Conditions
Chapter 4
Specification
+5°C to +40°C (41°F to 104°F)
-5°C to +55°C (23°F to 131°F)
30°C/h (54°F/h)
5 to 85%, but not to exceed 0.024 kg water per kg dry air
5 to 90%, but not to exceed 0.024 kg water per kg dry air
Client Layer Interface Port Module