[Sense:]Function:strain; [Sense:]Function:strain:fbending [<Range>,](@<Ch_List>); [Sense:]Function:strain:fbpoisson [<Range>,](@<Ch_List>); [Sense:]Function:strain:fpoisson [<Range>,](@<Ch_List>) - HP E1419A User Manual

Measurement and control module
Table of Contents

Advertisement

[SENSe:]FUNCtion:STRain

Parameters
Comments
Chapter 6
:FBENding
:FBPoisson
:FPOisson
:HBENding
:HPOisson
[:QUARter]
Note on Syntax: Although the strain function is comprised of six separate SCPI
commands, the only difference between them is the bridge type they specify to the
strain EU conversion algorithm.
[SENSe:]FUNCtion:STRain:<bridge_type> [<range>,](@<ch_list>) links the
strain EU conversion with the channels specified by ch_list to measure the bridge
voltage. See "Linking Input Channels to EU Conversion" on page 3-59 for more
information.
bridge_type is not a parameter but is part of the command syntax. The following
table relates the command syntax to bridge type. See the user's manual for the
optional Strain SCP for bridge schematics and field wiring information.
Command
:FBENding
:FBPoisson
:FPOisson
:HBENding
:HPOisson
[:QUARter]
Parameter
Parameter
Name
Type
range
numeric (flt32)
ch_list
channel list (string)
Strain measurements require the use of Bridge Completion Signal Conditioning
Plug-Ons.
Bridge Completion SCPs provide the strain measurement bridges and their
excitation voltage sources. ch_list specifies the voltage sensing channels that are
to measure the bridge outputs. Measuring channels on a Bridge Completion SCP
only returns that SCP's excitation source voltage.
Bridge Type
Full Bending Bridge
Full Bending Poisson Bridge
Full Poisson Bridge
Half Bending Bridge
Half Poisson Bridge
Quarter Bridge (default)
Range of
Values
see comments
1320 - 163
HP E1419 Command Reference 277
[SENSe]
Default
Units
VDC
none

Advertisement