Regulatory and Power Specifications

Electronic Authentication Specifications (Mobile Credentials)
For Mobile Credential-Enabled versions of this electronic lock
(Indicated by the credential code in the product order string):
• Mobile Credentials are transmitted to the lock via Bluetooth Smart or NFC ISO/IEC14443 and must use
a mobile device enabled with these technologies.
• Credential and mobile device versions are specified by the credential provider.
• User must acquire the latest HID "Mobile Access" application available from Apple iStore or Android PlayStore.
This product is not intended for outside wiring as covered by Article 800 in the National Electrical Code, NFPA 70.
Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294/B.
The system shall not be installed in the fail-secure mode unless permitted by the local authority having jurisdiction
and shall not interfere with the operation of Listed panic hardware.
• UL Listed - UL 294 Indoor Use
• CUL Listed - ULC-60839-11-1, Grade 1
Power Supply Specifications
IN220 (PoE version):
• Power over Ethernet:
Use UL 294 Listed, PoE Injector or Class 2 power limited power supply (55VDC, 90mA)
• UL testing was conducted on product powered by UL listed model POE20U-560(G) PoE Injector,
manufactured by Phihong
IN120 (Wi-Fi version):
• Battery Power:
Alkaline AA Batteries (6): 9V, 300mA
!
(To comply with "Fire Listed" doors, batteries must be replaced with alkaline batteries only)
• Optional Hard Power (UL 294 Listed Power Supply Required):
9-24VDC, 300mA
CAUTION: When using Hard Power, DO NOT install batteries.
CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical
Code (CEC), Part I, Safety Standard for Electrical Installations, local codes and the authorities having jurisdiction.
batteries according to the instructions.
• UL 294 Access Control Ratings:
Destructive Attack
Line Security
Endurance
Standby Power
4
Copyright © 2016, 2019, 2021, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written permission
of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
IN120 & IN220 Series
ED5200N / ED5600N Series
Exit Devices for 9100/9M100
Level 1
Level 1
Level 4
Level 1

Advertisement

Table of Contents
loading

Table of Contents