General Description; Features; Regulatory Specifications - Assa Abloy Corbin Russwin ED5200N Series Installation Instructions Manual

Exit devices for 9600 tcrne1 series trims m812 - iclass se reader option
Hide thumbs Also See for Corbin Russwin ED5200N Series:
Table of Contents

Advertisement

ED5200N Series Exit Devices
The Corbin Russwin Access 600 TCRNE1 Series exit device is designed to interface with existing Wiegand
Electrical Access Control (EAC) panels. The reader requires 12 or 24VDC for power and is compatible with HID
iCLASS SE
13.56 MHz technology. The Access 600 technology is designed around Corbin Russwin's Grade 1
®
hardware. The exit device comes with touch bar monitoring (REX) and is provided with an external Door
Position Switch (DPS). Featuring EcoFlex™ technology, the lock is field-configurable to fail-safe or fail-secure
and operates from 12-24VDC. Weatherseal gaskets are also included for outdoor applications. The Access
600 iCLASS SE reader provides visual (LED) and audible indication of lock state (locked/unlocked).
• Door Thickness – 1-3/4" Standard; Can be furnished for
other door thicknesses upon request. Consult factory.
• Outside lever controlled by reader or key allows lever
to retract latch
• Inside push bar produces REX (request to exit) signal
and retracts latch
• Fail Safe or Fail Secure Operation (must specify).
• UL fire listed available
• Wires directly to EAC panels
• Wire from EAC Panel to door must be shielded with a drain.
Drain terminated at EAC Panel controller
• McKinney QC12 Hinge with ElectroLynx
• Reader Draw = 150mA @12VDC / 24VDC
• Actuator Draw = 400mA inrush / 15mA continuous @12VDC / 24VDC
• Total System Draw = 550mA @12VDC / 24VDC
• UL 294 Access Control Performance Ratings:
UL294 6th Edition (Access Control System Units)
This product meets the requirements of CAN/ULC-S319-05 Equipment Class I
ANSI/BHMA A156.25 Listed Grade 1 Compliant ANSI/BHMA A156.25 Listed Grade 1 Compliant
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical
Code (CEC), Part I, Safety Standard for Electrical Installations, local codes, and the authorities having jurisdiction.
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.

2) General Description

3) Features

plug and play
®

4) Regulatory Specifications

3
• Supported credentials:
• iCLASS
®
• iCLASS SE
®
• iCLASS
Seos
®
• HID SIO on MIFARE
• HID SIO on MIFARE DESFire
• NFC-enabled mobile phones
Destructive Attack
Level I
Line Security
Level I
Endurance
Level IV
Standby Power
Level I
(SIO-enabled)
®
Classic
®
EV1
®

Advertisement