IN120 /IN220 Installation Instructions (Continued)
1
Install Outside Reader (Continued)
d. Feed cables/connectors through the inside mounting assembly (and gasket if required*).
Fig. 15b
e. When all connections have been made, tuck ferrite bead
and excess cable into wire hole on inside of door.
f. Secure the mounting assembly while ensuring proper
alignment of outside reader and tighten the (2) through-bolts
on the inside of the door to secure the reader (Fig. 15b).
g. Secure ground lug(s) with #6-32 machine screw (Fig.15c).
*Gasket is required for outdoor installations.
If installing with gasket; separate gasket from mounting plate to feed cables through holes as indicated (Fig. 1b).
Once cables/connectors are fed through, reattach gasket to mounting plate.
Inside of Door
Cat5e or higher cable
from hinge
For IN220 installation only
NOTE: Cable lengths exaggerated for illustrative purposes.
Gasket*
Mounting Plate
Through -
bolt
DPS
Reader Harness
Ground Lug
Ground wire for
IN220 (PoE)
24
Copyright © 2016, 2019, 2021, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written permission
of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
IN120 & IN220 Series
ED5200N / ED5600N Series
Exit Devices for 9100/9M100
Through -
bolt
Lock body
Harness
Fig. 15c
Ground Lugs