Features

All Access 600 Multi Point Locks
UL and CUL listed for use on Fire Doors
Multi point lock furnished for 1-3/4" doors
Fail safe or fail secure available
Door Position Switch (708F989) supplied for
monitoring
24VDC motor operated trim available
Wire from EAC Panel to door must be
shielded with a drain terminated at EAC
Panel controller
4

Regulatory Specifications

The M802 125 kHz (proximity) version
of the Open Architecture Wiegand
Access Control platform requires a
proximity card/fob/tag presentation
to gain entry. The 125 kHz reader
operates on 12 VDC.
The M812 13.56 MHz iCLASS®
(contactless) version of Open
Architecture Wiegand Access Control
Platform requires an iCLASS card/
fob/tag presentation to gain entry. The
13.56 MHz iCLASS reader operates
on 12VDC or 24VDC.
• UL 294 Access Control Performance Ratings*:
*For Non-ELR Configured Product
ANSI/BHMA A156.25 Listed Grade 1 Compliant
UL and CUL listed for use on Fire Doors
This product meets the requirements of CAN/ULC-S319-05 Equipment Class I
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1,
Canadian Electrical Code (CEC), Part I, Safety Standard for Electrical Installations, local codes, and the
authorities having jurisdiction.
For installation assistance contact Corbin Russwin
1-800-543-3658 • techsupport.corbinrusswin@assaabloy.com
Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Access 600 MP9800 Series Multi Point Lock
Cylinder override available for MP9800 with
Auxiliary Control
Access 600 M802
12VDC / 24VDC System:
• Reader Draw= 150mA
• Actuator Draw= 400mA
(inrush / 15mA continuous)
• Total System Draw = 550mA
12VDC System (MELR):
• Reader Draw = 150mA
• 12VDC MELR Module Draw =
850mA
• Total System Draw = 1 Amp
24VDC System (MELR):
• Reader Draw = 150mA
(Reader is always 12VDC)
• 24VDC MELR Module Draw =
700mA
• Total System Draw = 850mA
Destructive Attack
Line Security
Endurance
Standby Power
4
Access 600 M812
• Reader Draw= 125mA
• Actuator Draw= 400mA
(inrush / 15mA continuous)
• Total System Draw = 525mA
• Reader Draw = 125mA
• 12VDC MELR Module Draw=
850mA
• Total System Draw = 975mA
• Reader Draw = 125mA
• 24VDC MELR Module Draw =
700mA
• Total System Draw = 825mA
Level I
Level I
Level IV
Level I