Download Print this page

General Description; Features; Regulatory Specifications - Assa Abloy Corbin Russwin Access 600 ML20600 TCRNE1 Series Installation Instructions Manual

M812 - iclass se reader option
Hide thumbs Also See for Corbin Russwin Access 600 ML20600 TCRNE1 Series:

Advertisement

ML20600 Series Mortise Lock
The Corbin Russwin Access 600™ TCRNE1 Series mortise lock is designed to interface with existing Wiegand
Electronic Access Control (EAC) panels. The reader requires 12 or 24 VDC for power and is compatible with HID
iCLASS SE
13.56 MHz technology. The Access 600 technology is designed around Corbin Russwin's Grade 1
®
hardware. The mortise lock comes with complete door monitoring, which is all integrated inside the lockbody
and is available in 12VDC or 24VDC. The Access 600 reader provides visual (LED) and audible indication of lock
state (locked/unlocked). Weatherseal gaskets are also included for outdoor applications.
• Latch – Stainless Steel
(Easily field reversible without disassembling lockbody)
• Deadbolt – Stainless Steel
• Auxiliary Latch – Stainless steel, non-handed
• Door Thickness – 1-3/4" Standard; Can be furnished
for other door thicknesses upon request.
Consult factory.
• Case – 12 gauge heavy duty wrought steel
• Outside lever controlled by reader or key retracts latch
• Inside lever produces REX (request to exit) signal and
retracts latch and deadbolt
• Fail Safe or Fail Secure operation
• UL fire listed
• McKinney QC12 Hinge with ElectroLynx
12VDC System
• Reader Draw = 150mA
• Actuator Draw = 400mA inrush / 15mA
continuous @12VDC / 24VDC
• Total System Draw = 550mA
• UL 294 Access Control Performance Ratings:
UL294 6th Edition (Access Control System Units)
This product meets the requirements of CAN/ULC-S319-05 Equipment Class I
ANSI/BHMA A156.25 Listed Grade 1 Compliant
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical
Code (CEC), Part I, Safety Standard for Electrical Installations, local codes, and the authorities having jurisdiction.
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.

2) General Description

3) Features

plug and play
®

4) Regulatory Specifications

24VDC System
• Reader Draw = 150mA
• Actuator Draw = 400mA inrush / 15mA
• Total System Draw = 550mA
3
• Supported credentials:
• iCLASS
®
• iCLASS SE
• iCLASS
Seos
®
• HID SIO on MIFARE
• HID SIO on MIFARE DESFire
• NFC-enabled mobile phones
continuous@12VDC / 24VDC
Destructive Attack
Level I
Line Security
Level I
Endurance
Level IV
Standby Power
Level I
(SIO-enabled)
®
®
Classic
®
EV1
®